New Temporary Storage Declaration (TSD)

The final implementation date of the new Temporary Storage Declaration (TSD) / TSD is 16 November 2026. From this moment at the latest, you submit the TSD in two ways:

  • TSD message with master and house data;
  • TSD message with master data only.

View here Dutch Customs’ communication about this statutory change.

Recording of information session

The key changes were explained by Dutch Customs and Portbase in an information session. You can find it here:

Please note: this session refers to the old deadline; the correct deadline is 16 November 2026. See here the answers to the frequently asked questions during and after this session.

Planning for customers with system interface

Before go-live, successful testing in the test environment must have taken place, followed by a successful pilot in production. Only then can go-live take place. There is no time to wait—action is necessary!

It is crucial that you no later than 1 November:

  • Complete successful tests in the Portbase test environment;
  • Have moved all changes to production

If this is not completed before 1 November, we cannot guarantee a timely go-live.

Planning for customers using web screens

We will agree the exact date for switching to the new web screens of Cargo Declaration Import in mutual consultation.

From 16 November 2026 at 12:00, you enter all mandatory data.

Mandatory data in the TSD message

The following data must be reported:

Mandatory to include in the TSD message ENS via Portbase? No ENS via Portbase?
Type consignment (704/705), (must be the same as reported in the ENS)

No action required.

Portbase includes the reported document type in the TSD.

Action required.

You must send this data to Portbase so we can process it in the TSD.

A change in the IFTMCS message specifications or a switch to the API* is necessary.

HS code (six digits instead of the current four digits)

No action required. However, do include the six-digit code.

Include the six-digit HS code with the ENS. We will copy this into the TSD.

Action required.

You must send this six-digit code to Portbase so we can process it in the TSD.

A change in the IFTMCS message specifications or a switch to the API* is necessary.

RTO number (ferry & containers)

No action required.

Portbase has the RTO numbers of ferry and container terminals. We process these in the TSD.

No action required.

Portbase has the RTO numbers of ferry and container terminals. We process these in the TSD.

Bonded warehouse licence number (bulk)

Action required.

This number is not known to Portbase. We also do not receive it from Dutch Customs.
Enter this in the web screen; Portbase will create a new field.

Action required.

This number is not known to Portbase. We also do not receive it from Dutch Customs.
Enter this in the web screen; Portbase will create a new field.

Notify party may be stated, including telephone or email
Is the consignee known? Then you are not required to report the notify party.
Do you decide to do so anyway? Then you are required to also state an email address or telephone number for the notify party.
Is the consignee known? Then you are not required to report the notify party.
Do you decide to do so anyway? Then you are required to also state an email address or telephone number for the notify party.

*Would you like to send a TSD message with master and house data ?
Portbase facilitates this with an API interface. Contact sales for more information.

Would you like to send a TSD message with master data only? Then switch to the new IFTMCS message specifications or choose an interface via API.

Dutch Customs will not introduce the aforementioned TSR message (Temporary Storage Reuse).

New way of working

Dutch Customs prefers to receive the master and house data. Therefore:

• When we receive master and house data for the ENS (and the cargo is discharged in the Netherlands), we send a TSD message with master and house data to Dutch Customs.
• When we receive master data only for the ENS, we send a TSD message with master data.
• Only reporting a TSD and there is no ENS in advance? Dutch Customs prefers to receive the master and house data. We would like to receive this data so that we can send a TSD message with master and house data to Dutch Customs.
• The TSD message is sent per Bill of Lading (and no longer grouped per manifest/loading port). Dutch Customs wants to receive the message this way; therefore, the status is also returned at Bill of Lading level.

Related articles

Was this article helpful?

0 out of 0 found this helpful
Link copied to clipboard